LG Air Conditioners
- ₨201,000
- ₨100,000Key Feature: Cool Only, Fixed SpeedCapcity: 1 TonColor: WhiteBTU:12000Type: Wall Mount
- ₨140,000Model: S186DCPhase: 1Frequency: 50HzVoltage: 220-240VCapacity: Cooling T1
- ₨160,000Model: 186HCCooling Power in Tons: YesWarranty: Yes
- ₨185,000Specifications of LG Split Air Conditioner 1.0 Ton I12CGH DUALCOOL InverterDual Inverter Compressor™TUV RheinlandEnergy SavingFast CoolingCooling - Min ~ Rated ~ Max(kW): 0.88/3.52/3.87Cooling - Min ~ Rated ~ Max(Btu/h): 3,000/12,000/13,200Heating - Min ~ Rated ~ Max(kW): 0.88/3.52/4.04...
- ₨225,000Specifications of LG Split Air Conditioner 1.5 Ton BSNQ186K3A1 Dual InverterCapacity: 1.5 TonAC Functionality: Heating & CoolingAC Design: Wall MountInverter Type: DCCooling Capacity: 18000 BTUHeating Capacity: 18000 BTUGas: R 410a...
- ₨230,000Specifications of LG Split Air Conditioner 1.5 Ton I18CGH DUALCOOL InverterDual Inverter Compressor™TUV RheinlandEnergy SavingFast CoolingCooling - Min ~ Rated ~ Max(kW) 1.08/5.28/5.36Cooling - Min ~ Rated ~ Max(Btu/h) 3,685/18,000/18,300Heating - Min ~ Rated ~ Max(kW) 1.08/5.42/6.10...
- ₨325,000Specifications of LG Split Air Conditioner 2.0 Ton I24CGH DUALCOOL InverterDual Inverter Compressor™TUV RheinlandEnergy SavingFast CoolingCAPACITYCooling - Min ~ Rated ~ Max(kW) 1.26/6.45/7.18Cooling - Min ~ Rated ~ Max(Btu/h) 3,500/22,000/24,500...
LG Air Conditioners in Pakistan
Yasir Electronics currently lists LG split air conditioners across 1-ton, 1.5-ton and 2-ton classes. The range is technically mixed: it includes Tropical Dual Inverter models, non-tropical DUALCOOL inverter models and older fixed-speed or legacy listings. Selected LG ACs support Heat & Cool operation, ThinQ connectivity, Gold Fin corrosion protection and Auto Cleaning, but these features do not apply to every model.
Choosing the right LG AC starts with the room's actual cooling load rather than a tonnage label alone. Compare rated cooling output, inverter or fixed-speed design, T1/T3 application, heating requirement, smart features, outdoor conditions and installation needs. In Karachi, top-floor exposure, strong afternoon sun, large windows, humidity and poor insulation can all change the cooling load. Current LG AC pricing and availability are shown with the live product listings.
Current LG Air Conditioners at Yasir Electronics
| Model | Capacity / Cooling Output | Verified Technology | Function | Smart Connectivity |
|---|---|---|---|---|
| S4NWABJAF31 | 1 ton; 12,000 BTU/h rated | Tropical Dual Inverter, T3 | Heat & Cool | ThinQ |
| S4NWAHKLF31 | 1.5 ton; 18,000 BTU/h rated | Tropical Dual Inverter, T3 | Heat & Cool | ThinQ |
| S4NWBDK2F31 | 2 ton class; 22,000 BTU/h rated, 24,500 BTU/h max | Tropical Dual Inverter, T3 | Heat & Cool | ThinQ |
| I12CGH DUALCOOL | 1 ton; 12,000 BTU/h rated | Dual Inverter Compressor | Heat & Cool | Confirm on exact supplied unit |
| I18CGH DUALCOOL | 1.5 ton; 18,000 BTU/h rated | Dual Inverter Compressor | Heat & Cool | Smart ThinQ / Wi-Fi |
| I24CGH DUALCOOL | 2 ton class; 22,000 BTU/h rated, 24,500 BTU/h max | Dual Inverter Compressor | Heat & Cool | Smart ThinQ / Wi-Fi |
| 126HC | 1 ton; 12,000 BTU/h | Fixed speed | Cool Only | Not established |
| BSNQ186K3A1 | 1.5 ton; 18,000 BTU/h listed | Dual Inverter listed by Yasir | Heat & Cool | Not established |
| S186DC | 1.5-ton listing | Legacy model; exact climate data should be checked | Cooling listing | Not established |
| 186HC | Confirm exact supplied variant | Legacy listing | Confirm exact variant | Not established |
| S4VQ12K3A | Confirm exact supplied capacity | Dual Inverter listing | Confirm exact variant | Not established |
For exact specifications, use the full model number rather than assuming similarly named LG units share the same compressor, refrigerant, climate class or smart features.
What Do 1 Ton, 1.5 Ton and 2 Ton Mean?
AC tonnage describes a cooling-capacity class, not the physical weight of the indoor or outdoor unit. As a general conversion, one refrigeration ton is approximately 12,000 BTU/h of cooling capacity.
That round-number conversion is only a reference. Inverter models can publish minimum, rated and maximum cooling outputs. For example, the current I24CGH and S4NWBDK2F31 are marketed in the 2-ton class but have a rated cooling output of 22,000 BTU/h and a higher maximum output. Maximum output should not be presented as continuous rated capacity.
Room Size Alone Cannot Determine AC Tonnage
| Room Factor | Potential Cooling-Load Effect | Why It Matters |
|---|---|---|
| Top-floor roof exposure | Can increase heat gain | Roof insulation and solar exposure affect the room |
| West-facing sun | Can raise afternoon load | Walls and windows absorb direct solar heat |
| Large windows | Can increase solar and conductive gain | Glazing, curtains and shading matter |
| High ceiling | Increases conditioned air volume | More air and surface area may require cooling |
| Multiple occupants | Adds internal heat | People contribute sensible and latent heat |
| Computers/appliances | Adds internal heat | Relevant for offices and media-heavy rooms |
| Poor insulation or air leakage | Raises ongoing load | Cool air is harder to maintain |
Karachi conditions can add demanding factors such as warm outdoor temperatures, humid periods, top-floor roof heat and strong afternoon sun. These do not justify automatically moving every room up a tonnage class. For difficult rooms, a proper cooling-load assessment is more reliable than a rigid square-foot chart.
Cooling Load vs Tonnage
Cooling load is the amount of heat the room needs the AC to remove under real conditions. Tonnage is the equipment's capacity class. Good selection aims to match AC capacity to the actual heat load rather than simply choosing the largest available machine.
An undersized system can struggle during peak conditions. A substantially oversized system is not automatically better either; unnecessary capacity, cycling behaviour and humidity control can all affect comfort depending on the system and operating conditions.
What Is LG Dual Inverter Compressor?
LG Dual Inverter Compressor technology varies compressor operation to better match changing cooling demand. It should not be simplified as “two compressors” or “two motors.” LG describes the compressor as adjusting its speed rather than relying only on fixed full-on/full-off operation.
That ability can support steadier part-load operation, but it does not create a guaranteed electricity-bill saving for every household. Room load, set temperature, outdoor conditions, operating hours, insulation, sizing and maintenance still affect energy use.
Fixed-Speed vs Inverter LG ACs
| Factor | Fixed Speed | Inverter |
|---|---|---|
| Compressor operation | Typically regulates temperature through more on/off cycling | Can vary output to match changing load |
| Part-load control | More limited | Designed for variable output |
| Energy use | Depends on load and operating pattern | Also depends on load, sizing and operating pattern |
| Current Yasir example | 126HC | S4NW and DUALCOOL models where verified |
Rated, Minimum and Maximum Cooling Capacity
Variable-speed LG models may list minimum, rated and maximum cooling capacity. The rated figure describes the principal performance point, while the minimum and maximum show the range over which the system can modulate under specified conditions.
Cooling capacity is also different from electrical power input. BTU/h or kW of cooling describes heat-removal capability; watts of input describe electrical demand at a stated operating point. Do not compare these as though they were the same measurement.
T1 vs T3 Air Conditioners
T1 and T3 refer to different climate/application test conditions. T3 equipment is intended for higher-temperature climate conditions than T1 equipment, but T3 does not have one universal “works at exactly this maximum temperature” definition for every product.
LG's tropical S4NW models are positioned for high-ambient operation, while the I12CGH, I18CGH and I24CGH sit in LG's non-tropical DUALCOOL range. For Karachi, T3 can be relevant where outdoor heat is a genuine design requirement, but room load, efficiency, installation and the exact model still matter.
Heat & Cool vs Cool Only
A Cool Only model provides space cooling. A Heat & Cool split AC can reverse operation to provide heat-pump heating where the model is designed for it. Inverter technology does not automatically mean heating is included.
The current 126HC is listed as Cool Only, while the verified tropical S4NW models and current I12CGH/I18CGH/I24CGH DUALCOOL models publish both cooling and heating capacities.
LG DUALCOOL: I12CGH, I18CGH and I24CGH
The current I12CGH, I18CGH and I24CGH form a useful capacity progression with Dual Inverter Compressor technology and published minimum/rated/maximum cooling data. The I18CGH and I24CGH official regional pages also list Smart ThinQ Wi-Fi. Buyers should still compare each exact model rather than treating the family as one identical AC in three sizes.
For a current 1.5-ton example, you can view the LG I18CGH DUALCOOL. Buyers requiring a tropical 2-ton-class option can also review the LG S4NWBDK2F31.
LG ThinQ and Wi-Fi Are Model-Specific
ThinQ connectivity can allow compatible LG models to use app-based functions such as remote operation, temperature control, monitoring or scheduling, depending on the exact AC and software support. The tropical S4NWABJAF31, S4NWAHKLF31 and S4NWBDK2F31 listings have verified ThinQ support, as do the I18CGH and I24CGH official regional pages.
Wi-Fi is not required for normal local cooling. Do not assume every LG Dual Inverter AC, especially older models, includes ThinQ.
Gold Fin, Auto Cleaning and Coastal Conditions
Selected tropical S4NW models include Gold Fin, a corrosion-resistance treatment for the heat exchanger. Corrosion protection can be a useful consideration in humid or coastal environments, but it is not permanent immunity from corrosion and does not remove normal maintenance requirements.
Auto Cleaning is also model-specific. It relates to LG's defined internal cleaning/drying function; it does not mean the AC automatically cleans every filter, the outdoor condenser or all internal components.
LG ACs and Humidity
Air conditioners remove some indoor moisture as part of the cooling process. Selected LG models also provide Dry or dehumidification modes. A split AC is still primarily a temperature-control system, not a dedicated humidity appliance.
If excess humidity is the main problem even when room temperature is already comfortable, compare the role of a dedicated dehumidifier rather than assuming stronger AC cooling is the only answer.
Choosing an LG AC for a Bedroom, Lounge or Office
For a bedroom, consider cooling load, sun exposure, capacity and verified sound or sleep-mode features. For a lounge, include ceiling height, occupancy, glazing and any connected open areas. For an office, add computers, lighting, door opening and longer daily operating hours to the load assessment.
A room's name does not determine its tonnage. A sun-exposed top-floor bedroom can have a different load from a shaded room of similar floor area.
Installation Quality Matters
AC performance depends on both the product and the installation. Important factors include indoor-unit positioning, outdoor-unit airflow, refrigerant piping, pipe insulation, condensate drainage, electrical supply and correct commissioning.
The outdoor unit needs unobstructed heat rejection and service access according to the exact installation manual. Outdoor sunlight is not automatically prohibited, but any shading arrangement must not block airflow. Do not assume copper piping, brackets, cables, drain pipe or installation labour are included unless the exact package confirms them.
Electrical, Solar and Backup-Power Planning
Use the exact model's voltage, frequency and electrical input when planning installation. Do not infer current draw solely from tonnage or copy requirements from another LG model.
Likewise, “inverter AC” does not automatically mean a unit will work on a particular solar or UPS system. Compatibility depends on AC input characteristics, inverter capacity, battery/storage, solar array, other loads and overall system design.
Basic LG AC Maintenance
Clean user-serviceable filters according to the exact manual, keep outdoor-unit airflow clear and ensure condensate drainage remains serviceable. Dust level and usage determine how often maintenance is needed, so there is no single cleaning interval for every home.
Refrigerant charging, compressor work, PCB repair and internal electrical servicing should be left to appropriately trained technicians.